Availability: | |
---|---|
Quantity: | |
SCE238D003
ASCO
ASCO SCE238D003 DN15 Orifice size 15mm Normally Closed 2/2 Way Brass Solenoid Valve
FEATURES
1. Minimum operating pressure differential ΔP 0.3/0.5 bar
2. Two way valves for automatic control of water, air and inert gas and other gases/liquids compatible with the sealing materials used
3. Interchangeability of magnetic heads, AC and DC
4. The solenoid valves satisfy all relevant EC Directives
OPTIONS
1. Valves can also be supplied with FPM (fluorelastomer), EPDM (ethylene-propylene) seals, diaphragm and disc. Use the appropriate optional
suffix letter for identification
2. Oxygen service, suffix NV, example: SCE238C002NVMO (Except pipe size G 1 1/4, G 1 1/2 and G 2)
3. Plug with visual indication and peak voltage suppression or with cable length of 2 m (see Solenoids, Coils & Accessories section)
MATERIALS IN CONTACT WITH FLUID
Body: Brass
Internal parts: Stainless steel and brass
Springs: Stainless steel
Diaphragm & valve disc: NBR
Seals and pilot disc: FPM (38 to 1), NBR (1 14 to 2)
Shading coil: Copper
SPARE PARTS KIT
Catalog Number | Spare Parts Kit Number | |
diaphragm | armature | |
~/= | ~/= | |
SCE238D001 | C131600 | C140262V |
SCE238D002 | C131600 | C140262V |
SCE238D006 | C131600 | C140262V |
SCE238D007 | C131600 | C140262V |
SCE238D003 | C131618 | C140262V |
SCE238D008 | C131618 | C140262V |
SCE238D004 | C131606 | C140262V |
SCE238D009 | C131606 | C140262V |
SCE238D005 | C131609 | C140262V |
SCE238D010 | C131609 | C140262V |
INSTALLATION
1. The solenoid valves can be mounted in any position without affecting operation
2. Pipe connections (G*) have standard combination thread according to ISO 228/1 and ISO 7/1. Pipe connections (G) have standard combination thread according to ISO 228/1
3. Installation/maintenance instructions are included with each valve
4. Spare parts kits and replacement coils are available
5. Other pipe connections are available on request
Dimension
ASCO SCE238D003 DN15 Orifice size 15mm Normally Closed 2/2 Way Brass Solenoid Valve
FEATURES
1. Minimum operating pressure differential ΔP 0.3/0.5 bar
2. Two way valves for automatic control of water, air and inert gas and other gases/liquids compatible with the sealing materials used
3. Interchangeability of magnetic heads, AC and DC
4. The solenoid valves satisfy all relevant EC Directives
OPTIONS
1. Valves can also be supplied with FPM (fluorelastomer), EPDM (ethylene-propylene) seals, diaphragm and disc. Use the appropriate optional
suffix letter for identification
2. Oxygen service, suffix NV, example: SCE238C002NVMO (Except pipe size G 1 1/4, G 1 1/2 and G 2)
3. Plug with visual indication and peak voltage suppression or with cable length of 2 m (see Solenoids, Coils & Accessories section)
MATERIALS IN CONTACT WITH FLUID
Body: Brass
Internal parts: Stainless steel and brass
Springs: Stainless steel
Diaphragm & valve disc: NBR
Seals and pilot disc: FPM (38 to 1), NBR (1 14 to 2)
Shading coil: Copper
SPARE PARTS KIT
Catalog Number | Spare Parts Kit Number | |
diaphragm | armature | |
~/= | ~/= | |
SCE238D001 | C131600 | C140262V |
SCE238D002 | C131600 | C140262V |
SCE238D006 | C131600 | C140262V |
SCE238D007 | C131600 | C140262V |
SCE238D003 | C131618 | C140262V |
SCE238D008 | C131618 | C140262V |
SCE238D004 | C131606 | C140262V |
SCE238D009 | C131606 | C140262V |
SCE238D005 | C131609 | C140262V |
SCE238D010 | C131609 | C140262V |
INSTALLATION
1. The solenoid valves can be mounted in any position without affecting operation
2. Pipe connections (G*) have standard combination thread according to ISO 228/1 and ISO 7/1. Pipe connections (G) have standard combination thread according to ISO 228/1
3. Installation/maintenance instructions are included with each valve
4. Spare parts kits and replacement coils are available
5. Other pipe connections are available on request
Dimension